Humidity Chamber / Stability Chamber

  • Designed for testing product shelf – life, packing and electronic test.
  • Specially designed to meet ICH, WHO & USFDA requirements.
  • Double walled having Inner 304 SS chamber and Exterior finished in Powder Coated Shade in REGULAR MODEL.
  • Inner SS 304/SS 316 and Exterior SS 304 matt/buff finish in GMP MODEL.
  • The Temp. & Humidity controlled by Microprocessor based PID Temp. & RH% Controller with Dual Digital Indicator & PT – 100 sensor for Temp. & imported sensor for RH%.
  • Cooling Kit is CFC Free. The Cooling Kit includes hermetically sealed compressor, condenser, Fan Motor, etc. and are safely placed below/above the chamber
  • Humidification through steam injection system. Humidity levels from 40% RH to 95% RH & depends on Temperature i.e. lower temp. lower humidity higher the temp. higher humidity. Humidity Stability :- 2% RH to ± 3% RH
  • Air Circulation system ensures more stability of condition & even distribution inside the chamber.
  • A Boiler Tank consisting of Water Heater having auto cut off facility with Audio Alarm for low water level.
  • Reservoir Water Tank having float Valve provided.
  • Overload protection relay & time delay for compressor.
  • Adjustable SS Rod type shelves with all units as standard.
  • A two pan glass window provided on door for clear observation of test. An ancillary type heater provided in between the glass to cut the condensation.
  • The illumination is provided through fluorescent tubes for clear visibility of test
Photostability Chamber
Cat No.
Inner Size (W x D x Ht.)
Temp. Range
RH. Range
Shelves
Capacity Ltrs.
Capacity CFT
CIC - 64
18" x 18" x 28"
10oC - 60oC
40% - 95%
2
150 Ltrs.
5.25 CFT
CIC - 64
24" x 24" x 24"
10oC - 60oC
40% - 95%
3
228 Ltrs.
8 CFT
CIC - 64
24" x 24" x 36"
10oC - 60oC
40% - 95%
3
342 Ltrs.
12 CFT
CIC - 64
24" x 24" x 36"
10oC - 60oC
40% - 95%
4
400 Ltrs.
14 CFT
CIC - 64
36" x 36" x 40"
10oC - 60oC
40% - 95%
5
850 Ltrs.
30 CFT
CIC - 64
38" x 38" x 44"
10oC - 60oC
40% - 95%
6
1040 Ltrs.
36 CFT

Optional

  • PRINTER OUTPUT facility required to record PV, SV, Actual Date/Time with variable print time interval, 5000 line memory & Audio alarm facility in case of memory full.
  • TEMP. SCANNER 4 Channel/8 Channel with Printer Output facility to record temp. & RH at various places inside chamber.
  • PLC Based Touch screenControl System with printer OUTPUT facility
  • AUTOCHANGE OVER to stand by Cooling System
  • GSM mobile alert.
  • 21 CFR PART 11 COMPLIANCE SOFTWARE for Data Management.
  • ALARM HOOTER facility.